Some stoves are equipped with a combustor
view port, it should be noted that the combustor usually glows during the first
20 to 35% of the burn cycle when the catalyst is receiving the most smoke and
burning at a high temperature. The combustor temperature can reach 1000 F. and
produce a glow. However, the combustor does not have to glow to be
working. As less smoke is present to burn, the combustor temperature
drops and the glow will cease. Therefore, it is suggest this not be a method of
determining whether or not the combustor is working.
-The best method is the use of thermo couplings and following the manufacturer’s instructions.
This method will read the inlet and exhaust temperatures of the combustor.
-A more simple method is to visually observe the exhaust coming out of the chimney. When the by-pass is in the closed position and the catalytic combustor is in good operating condition, there should be no dark smoke coming out of the chimney.
-If the catalytic combustor is not working properly, the stove’s operator will notice an increase in fuel usage.
-The stove’s operator will also notice an increase build-up of creosote in the system.